Search results for "Refractive lens"

showing 10 items of 10 documents

Clinical Impact of a Spontaneous Decentration of a Phakic Refractive Lens

2011

PURPOSE To evaluate the clinical impact and possible causes of a spontaneous decentration of a phakic refractive lens (PRL) implanted in a highly myopic eye, and analyzing the visual, refractive, and aberrometric outcome as well as the possible causes for this phenomenon. METHODS The description of a case of bilateral high myopia corrected by implantation with the phakic intraocular lens (pIOL) PRL (Carl Zeiss Meditec, Germany) is presented and documented. Both eyes had similar anatomical configuration, and therefore, a pIOL (Model 101) with the same size was implanted without any associated intraoperative complication. Clinical outcomes were evaluated during a 3-month follow-up. RESULTS Im…

AdultMalePhakic Intraocular Lensesmedicine.medical_specialtyDistance visual acuitygenetic structuresVisual AcuityComa (optics)Anatomical configurationRefraction OcularPhakic intraocular lensPostoperative ComplicationsOphthalmologyAberrometryMyopiamedicineHumansbusiness.industryLens SubluxationRefractive lensSubjective refractioneye diseasesOphthalmologySpherical aberrationsense organsbusinessFollow-Up StudiesOptometryOptometry and Vision Science
researchProduct

Refractive lens exchange with the Acri. Twin asymmetric diffractive bifocal intraocular lens system

2009

PURPOSE To evaluate efficacy, safety, and predictability after refractive lens exchange (RLE) in patients who had implantation of asymmetric Acri.Twin bifocal diffractive intraocular lenses. METHODS The study comprised 130 eyes of 65 consecutive patients after RLE who had bilateral implantation of the Acri.Twin system. Eyes were divided into myopic and hyperopic groups. Binocular uncorrected distance visual acuity, best-corrected distance visual acuity (BCVA), uncorrected distance near visual acuity, and best distance-corrected near visual acuity (BCNVA) were recorded preoperatively and 6 months after surgery. RESULTS Efficacy indexes were 0.99 for myopic and 0.93 for hyperopic patients at …

AdultMaleReoperationmedicine.medical_specialtyVisual acuityDistance visual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensRefractive lens exchangeFunctional Laterality03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologyMyopiamedicineHumansIn patientProspective StudiesAgedLenses IntraocularPhacoemulsificationbusiness.industryPresbyopiaGeneral MedicinePresbyopiaMiddle AgedMultifocal intraocular lensmedicine.diseaseeye diseasesOphthalmologyHyperopiaIntraocular lenses030221 ophthalmology & optometryFemalesense organsmedicine.symptombusiness030217 neurology & neurosurgeryEuropean Journal of Ophthalmology
researchProduct

Refractive lens exchange with an array multifocal intraocular lens.

2002

ABSTRACT PURPOSE: To prospectively evaluate safety, efficacy, predictability, stability, complications, and patient satisfaction after refractive lens exchange (clear lens extraction) followed by posterior chamber implantation of a multifocal intraocular lens (IOL). METHODS: Fifty eyes of 25 patients (mean age 51 years, range 44 to 62 years) with preoperative spherical equivalent refraction between -15.50 and +5.75 D and cylinder between 0 and 1.50 D underwent bilateral implantation of a zonal progressive multifocal IOL (Array, AMO). RESULTS: Eyes were divided into group A (n=24; myopia, average preoperative spherical equivalent refraction -7.11 ± 3.25 D (-1.75 to -15.50 D), and group B (n=…

AdultMalemedicine.medical_specialtyIntraocular pressureVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensRefractive lens exchangeRefraction Ocularlaw.inventionPostoperative ComplicationsLens Implantation IntraocularlawOphthalmologymedicineMyopiaHumansProspective StudiesIntraocular PressureLenses IntraocularClear lens extractionbusiness.industryMultifocal intraocular lensMiddle AgedRefractioneye diseasesSurgeryLens (optics)OphthalmologyHyperopiaTreatment OutcomePatient SatisfactionSurgeryFemalesense organsmedicine.symptomSafetybusinessJournal of refractive surgery (Thorofare, N.J. : 1995)
researchProduct

Fixed Mydriatic Pupil Associated with an Intraocular Pressure Rise as a Complication of the Implant of a Phakic Refractive Lens (PRL)

2013

We describe a case report of a patient that was implanted with a posterior chamber phakic intraocular lens (Phakic Refractive Lens, PRL) for the correction of moderate myopia and who developed postoperatively a fixed mydriasis compatible with an Urrets-Zavalia Syndrome (UZS). Specifically, a sudden acute increase of IOP in the left eye was observed in the immediate postoperative period. After IOP stabilization, the refractive result was good, but a fixed and mydriatic pupil appeared. This condition led the patient to experience visual discomfort, halos, and glare associated with high levels of higher-order aberrations in spite of the good visual result. A tinted-contact lens was fitted in o…

AdultPhakic Intraocular Lensesmedicine.medical_specialtygenetic structuresVisual AcuityVisual DiscomfortSuctionPhakic intraocular lensPhakic intraocular lensIris atrophyLens Implantation IntraocularOphthalmologyMyopiamedicineMydriasisHumansAntihypertensive AgentsIntraocular PressureÓpticabusiness.industryMydriasisGlare (vision)General MedicineRefractive lensCombined Modality Therapyeye diseasesOphthalmologymedicine.anatomical_structureSecondary glaucomaLens (anatomy)OptometryFemaleOcular Hypertensionsense organsImplantmedicine.symptomComplicationbusinessUrrets-Zavalia syndromeSeminars in Ophthalmology
researchProduct

Refractive lens exchange with a multifocal diffractive aspheric intraocular lens

2012

PURPOSE: To evaluate the safety, efficacy and predictability after refractive lens exchange with multifocal diffractive aspheric intraocular lens implantation. METHODS: Sixty eyes of 30 patients underwent bilateral implantation with AcrySof® ReSTOR® SN6AD3 intraocular lens with +4.00 D near addition. Patients were divided into myopic and hyperopic groups. Monocular best corrected visual acuity at distance and near and monocular uncorrected visual acuity at distance and near were measured before and 6 months postoperatively. RESULTS: After surgery, uncorrected visual acuity was 0.08 ± 0.15 and 0.11 ± 0.14 logMAR for the myopic and hyperopic groups, respectively (50% and 46.67% of patients ha…

MaleVisual acuitygenetic structuresDesenho de prótesesmedicine.medical_treatmentVisual AcuityEmmetropiaIntraocular lensProsthesis designMyopia/surgerylaw.inventionNear visionLens Implantation Intraocularlcsh:OphthalmologylawTonometry ocularMyopiaProspective StudiesLenses IntraocularLens crystalline/surgeryAcuidade visualGeneral MedicineMiddle AgedLens (optics)HyperopiaTreatment OutcomeFemalemedicine.symptomLens crystallinemedicine.medical_specialtyVisual acuityMiopiaRefractive lens exchangeProsthesis DesignStatistics NonparametricOphthalmologyLens CrystallinemedicineHumansHyperopia/physiopathologyHipermetropiaCristalinoAgedPhacoemulsificationbusiness.industryReproducibility of ResultsPhacoemulsificationPresbyopiamedicine.diseaseeye diseasesOphthalmologyLens implantation intraocularlcsh:RE1-994OptometryImplantação de lentes intraocularessense organsbusinessArquivos Brasileiros de Oftalmologia
researchProduct

Refractive lens exchange with Acri.LISA bifocal intraocular lens implantation.

2011

PURPOSE To assess efficacy, safety, and predictability after refractive lens exchange (RLE) in patients who had bilateral implantation of an Acri.LISA 366D diffractive bifocal intraocular lens (IOL). METHODS Sixty-six eyes of 33 consecutive patients were examined after RLE who had bilateral implantation of an Acri.LISA bifocal 366D IOL. Eyes were divided into myopic and hyperopic groups. Monocular uncorrected distance visual acuity, best-corrected distance visual acuity (BCVA), uncorrected distance near visual acuity, and best distance-corrected near visual acuity (BCNVA) were recorded preoperatively and 6 months after surgery. RESULTS Efficacy indexes were 0.73 for myopic and 0.85 for hype…

Malemedicine.medical_specialtyDistance visual acuityVisual acuitygenetic structuresmedicine.medical_treatmentVisual AcuityIntraocular lensRefractive lens exchangeNear visual acuityFunctional Laterality03 medical and health sciences0302 clinical medicineLens Implantation IntraocularOphthalmologymedicineMyopiaHumansIn patientLenses IntraocularPhacoemulsificationbusiness.industryGeneral MedicinePhacoemulsificationPresbyopiaPresbyopiaMiddle Agedmedicine.diseaseeye diseasesOphthalmologyHyperopiaTreatment Outcome030221 ophthalmology & optometryFemalesense organsmedicine.symptombusiness030217 neurology & neurosurgeryEuropean journal of ophthalmology
researchProduct

Refractive Lens Exchange with Foldable Toric Intraocular Lens

2009

To assess visual and refractive outcomes, and rotational stability after refractive lens exchange (RLE) with toric intraocular lens (IOL) implantation to correct ametropia and preexisting astigmatism.Prospective, nonrandomized, observational case series (self-controlled).This prospective, nonrandomized, and self-controlled study included 32 eyes of 19 consecutive patients with more than 1.00 diopter (D) of preexisting corneal astigmatism having RLE with AcrySof Toric IOL implantation (Alcon Laboratories Inc, Fort Worth, Texas, USA). Uncorrected visual acuity (UCVA), best-corrected visual acuity (BCVA), refractive sphere, and keratometric and refractive cylinder were recorded preoperatively …

Malemedicine.medical_specialtyVisual acuitygenetic structuresmedicine.medical_treatmentAcrylic ResinsVisual AcuityIntraocular lensVisual phenomenaAstigmatismRefractive lens exchangeRefraction OcularLens Implantation IntraocularSurveys and QuestionnairesOphthalmologyMyopiamedicineHumansProspective StudiesDioptreAgedLenses IntraocularPhacoemulsificationbusiness.industryAstigmatismMiddle Agedmedicine.diseaseeye diseasesOphthalmologyAlcon LaboratoriesEyeglassesPatient SatisfactionOptometryFemalesense organsmedicine.symptombusinessCorneal astigmatismAmerican Journal of Ophthalmology
researchProduct

Effect of Multizone Refractive Multifocal Contact Lenses on Standard Automated Perimetry

2012

PURPOSE The aim of this study was to evaluate whether the creation of 2 foci (distance and near) provided by multizone refractive multifocal contact lenses (CLs) for presbyopia correction affects the measurements on Humphreys 24-2 Swedish interactive threshold algorithm (SITA) standard automated perimetry (SAP). METHODS In this crossover study, 30 subjects were fitted in random order with either a multifocal CL or a monofocal CL. After 1 month, a Humphrey 24-2 SITA standard strategy was performed. The visual field global indices (the mean deviation [MD] and pattern standard deviation [PSD]), reliability indices, test duration, and number of depressed points deviating at P<5%, P<2%, P<1%, an…

Malemedicine.medical_specialtygenetic structuresContact LensesOpticsCLs upper limitsPattern standard deviationOphthalmologymedicineHumansMathematicsCross-Over Studiesbusiness.industryAutomated perimetryPresbyopiaPresbyopiaMiddle Agedmedicine.diseaseRefractive lensCrossover studyeye diseasesVisual fieldAbsolute deviationOphthalmologySensory ThresholdsVisual Field TestsFemaleVisual FieldsbusinessAlgorithmsEye &amp; Contact Lens: Science &amp; Clinical Practice
researchProduct

The posterior chamber phakic refractive lens (PRL): a review

2012

Implantation of phakic intraocular lenses (pIOLs) is a reversible refractive procedure, preserving the patient’s accommodative function with minimal induction of higher order aberrations compared with corneal photoablative procedures. Despite this, as an intraocular procedure, it has potential risks such as cataracts, chronic uveitis, pupil ovalization, corneal endothelial cell loss, pigmentary dispersion syndrome, pupillary block glaucoma, astigmatism, or endophthalmitis. Currently, only two models of posterior chamber pIOLs are commercially available, the implantable collammer lens (STAAR Surgical Co.) and the phakic refractive lens (PRL; Zeiss Meditec). The number of published reports on…

Phakic Intraocular Lensesmedicine.medical_specialtygenetic structuresmedicine.medical_treatmentVisual performanceOptical qualityReviewAstigmatismRefraction OcularPhakic intraocular lensPhakic refractive lens (PRL)CataractPupilEndophthalmitisLens Implantation IntraocularCataractsOphthalmologyRefractive surgeryMyopiamedicineHumansRefractive surgeryÓpticaPosterior chamber phakic intraocular lensbusiness.industryPatient SelectionEquipment Designmedicine.diseaseeye diseasesOphthalmologyAberrations of the eyemedicine.anatomical_structureLens (anatomy)Posterior Capsule of the LensOptometrysense organsbusinessEye
researchProduct

Preliminary in vivo positional analysis of a posterior chamber phakic intraocular lens by optical coherence tomography and its correlation with clini…

2012

Purpose: To analyze by spectral-domain optical coherence tomography the anatomical relationship of a specific type of posterior chamber phakic intraocular lens (pIOL) implanted in cases of high to moderate myopia with the adjacent intraocular structures and to correlate it with clinical outcomes. Methods: Prospective observational case series including 18 eyes with high to moderate myopia (spherical equivalent between −5.88 and −15.75 D) of 9 patients (age range, 29–49 years) undergoing bilateral Phakic Refractive Lens (PRL, Zeiss) implantation. Postoperative visual acuity, refraction, contrast sensitivity (CS), and ocular higher order aberrations (HOA) were evaluated. Furthermore, the in v…

medicine.medical_specialtygenetic structuresSpectral domainPositional analysislcsh:OphthalmologyOptical coherence tomographyIn vivoOphthalmologymedicinelcsh:QC350-467Optical coherence tomographymedicine.diagnostic_testbusiness.industrySpectral-domaineye diseasesPosterior chamber phakic intraocular lensTomografía de coherencia ópticaLentes refractivas fáquicaslcsh:RE1-994Anatomical relationshipOriginal Articlesense organsDominio espectralPhakic Refractive Lens (PRL)businesslcsh:Optics. LightOptometryJournal of Optometry
researchProduct